Z900 Zone Planning Instructions.. | ||||||||||||||||||
| Zone Type | Definition | Value |
| |||||||||||||||
| 01 | 02 | 03 | 04 | 05 | 06 | |||||||||||||
|
Burglar Loops |
Entry Delay 1 Instant Silent instant Entry Delay 2 Interior Non-Shuntable Slow Response Supervisory/TBL |
= 0 = 1 = 7 = 8 = 16 = 32 = 64 = 128 | ||||||||||||||||
| Auxiliary "A" |
(Fire) Shuntable Slow Response |
= 2 = 32 = 64 | ||||||||||||||||
| Auxiliary "B" |
(Police) No Aux "B" alarm output No Violation output on Z729 Shuntable Slow Response Supervisory/TBL |
= 3 = 8 = 16 = 32 = 64 = 128 | ||||||||||||||||
| Auxiliary "C" |
(Emergency) Shuntable Slow Response Supervisory/TBL |
= 4 = 32 = 64 = 128 | ||||||||||||||||
| KeySwitch |
Momentary Maintained Type Shuntable Supervisory/TBL |
= 5 = 16 = 32 = 128 | ||||||||||||||||
| Communicator |
Report Only Shuntable Slow Response Supervisory/TBL |
= 6 = 32 = 64 = 128 | ||||||||||||||||
| Total Value for Selected Zone Type = | (__) | (__) | (__) | (__) | (__) | (__) | ||||||||||||
| Function # for entering value total | 41 | 42 | 43 | 44 | 45 | 46 | ||||||||||||
|
Default values are: Zone 1= (41)= 64 (entry delay 1 (0) + slow response (64) Zone 2= (42)= 72 (entry delay 2 (8) + slow response (64) Zone 3= (43)= 81 (instant (1) + interior (16) + slow response (64) Zone 4= (44)= 65 (instant (1) + slow response (64) Zone 5= (45)= 65 (instant (1) + slow response (64) Zone 6= (46)= 66 (fire (2) + slow response (64)
| | |||||||||||||||||